FASTPCBA


  • English
Email:pcba13@fastpcba.cn

Pcb supplier component picking error reason and solution

date:2019-10-18 17:11:58

Pcb supplier component picking error reason and solution


1. The suction coordinate (X, Y) setting of "Absorb data" is incorrect. In the case of the tray element, the "element start position, pitch" setting of "element data" becomes the initial value of the suction data. Therefore, the pcb supplier should correctly input the "component start position, pitch, component number" of "component data".

Measure: Reset the suction coordinates (X, Y)


Pcb supplier component picking error reason and solution


2. The suction height (Z) setting of "Absorb data" is incorrect. In this case, the nozzle is not enough for the component, or it cannot be sucked due to the reaction force generated by the excessive pressing.

Measure: Reset the suction height (Z)



3. The nozzle selection is wrong. Especially when the component has a small suction nozzle, it cannot be sucked or detached in the middle.

Measure: Reselect the nozzle. The pcb supplier selects a nozzle that stabilizes the sucked element.


4. "Additional information" of "Component data" is not set correctly.

Measure:  Set the appropriate push in amount


5. The surface of the component is uneven

Measure:In the "expansion" of the measure "component data", the pcb supplier sets the suction speed to medium or low speed.


6. The surface of the laser is dirty

Measure: Clean the laser surface


7. "Transfer pitch" setting of "Component data" is not correct.

Measure:  Set the appropriate "transfer spacing" in the "Package Form" of "Component Data"